rfmeasurement:testing_fixture_6_lead_qfn_spdt_rf_switch [2021/10/26 06:56] – [The De-embedded Measurements] neilhaorfmeasurement:testing_fixture_6_lead_qfn_spdt_rf_switch [2021/10/26 16:28] – [Summary] neilhao
Line 23: Line 23:
 Unfortunately, the measurement data exceed the isolation specifications in datasheet. Unfortunately, the measurement data exceed the isolation specifications in datasheet.
 ===== Summary ===== ===== Summary =====
-The testing fixture meets my expectation for working within 0GHz to 6GHz. No comment for the SPDT RF switch.+The testing fixture meets my expectation for working within 0GHz to 6GHz. For the isolation, I think the IC may conform to the isolation specifications, because de-embedded algorithm cannot work with crosstalk problem. Crosstalk between the traces RF1 and RF2 on the PCB can downgrade the isolation.
  